Blocks produced not being distributed to the network
Affected
Partial outage from 6:03 PM to 6:23 PM, Operational from 6:23 PM to 7:35 PM
Partial outage from 6:03 PM to 6:23 PM, Operational from 6:23 PM to 7:35 PM
- Postmortem · UTC
OP Mainnet external nodes and RPC providers stalled on a stale head (7 July 2026)
Status: Resolved
ImpactExternal nodes and third-party RPC providers were stuck at a stale head for ~22 minutes (17:59 to 18:22 UTC). Because major providers were serving that stale head, transaction throughput was near zero for about 16 minutes of that window, and submissions routed through those providers did not land. Reads continued to be served, though against a stale state. There was no reorg, no safe-head or finality violation, and no funds were at risk.
Root causeA routine infrastructure upgrade disrupted a network connection our sequencers depend on. The connection failed silently rather than erroring, which throttled block production and pushed new blocks outside the window for normal peer-to-peer propagation. External nodes recovered once the affected range was posted to L1
RemediationWe deployed a fix removing the dependency responsible for the slowdown and made the affected connections fail cleanly when infrastructure cycles. We're also strengthening internal alerting and node peering so issues of this kind are detected and contained faster.
- Resolved · UTCThis incident has been resolved.
- Monitoring · UTC
Most infrastructure providers have recovered, we are continuing to monitor and work with infrastructure providers to resolve syncing issues.
- Investigating · UTC
We are currently investigating this incident after a brief unsafe head stall. The sequencer is now producing blocks but some nodes participating in the network are not syncing.